Monoaxial Pedicle Screws feature a fixed, non-movable head that provides maximum rigidity and stability, making them ideal for procedures requiring firm spinal fixation and precise vertebral alignment. Their solid design allows surgeons to apply strong corrective forces during deformity correction or trauma stabilization, ensuring reliable control of spinal positioning throughout the fusion process.
Indications:| Codes / Diameter | ||||
|---|---|---|---|---|
| Length in mm | 4.5 mm | 5.5 mm | 6.5 mm | 7.5 mm |
| 25 | 8500.45.25 | 8500.55.25 | 8500.65.25 | 8500.75.25 |
| 30 | 8500.45.30 | 8500.55.30 | 8500.65.30 | 8500.75.30 |
| 35 | 8500.45.35 | 8500.55.35 | 8500.65.35 | 8500.75.35 |
| 40 | 8500.45.40 | 8500.55.40 | 8500.65.40 | 8500.75.40 |
| 45 | 8500.45.45 | 8500.55.45 | 8500.65.45 | 8500.75.45 |
| 50 | 8500.45.50 | 8500.55.50 | 8500.65.50 | 8500.75.50 |
Polyaxial Pedicle Screws feature a movable, multidirectional head that allows precise adjustment during surgery, facilitating easy and accurate rod placement. This flexibility helps surgeons achieve optimal spinal alignment while minimizing stress on the implant and surrounding bone. The design enhances intraoperative versatility and ensures secure fixation across various spinal levels.
Indications:| Codes / Diameter | ||||
|---|---|---|---|---|
| Length in mm | 4.5 mm | 5.5 mm | 6.5 mm | 7.5 mm |
| 25 | 8505.45.25 | 8505.55.25 | 8505.65.25 | 8505.75.25 |
| 30 | 8505.45.30 | 8505.55.30 | 8505.65.30 | 8505.75.30 |
| 35 | 8505.45.35 | 8505.55.35 | 8505.65.35 | 8505.75.35 |
| 40 | 8505.45.40 | 8505.55.40 | 8505.65.40 | 8505.75.40 |
| 45 | 8505.45.45 | 8505.55.45 | 8505.65.45 | 8505.75.45 |
| 50 | 8505.45.50 | 8505.55.50 | 8505.65.50 | 8505.75.50 |
Monoaxial Reduction Pedicle Screws are designed to assist surgeons in gradually realigning displaced vertebrae during spinal fusion surgeries. Featuring a fixed screw head and extended tulip heads (tabs), these screws allow controlled vertebral reduction and precise rod placement, providing rigid fixation and strong anchorage in the vertebrae. Their robust design facilitates effective load transfer, maintaining spinal alignment throughout complex spinal deformity corrections.
These screws are particularly suitable for controlled reduction maneuvers, offering enhanced stability when realigning vertebrae or correcting malpositioned instrumentation.
Indications:| Codes / Diameter | |||
|---|---|---|---|
| Length in mm | 4.5 mm | 5.5 mm | 6.5 mm |
| 25 | 8510.45.25 | 8510.55.25 | 8510.65.25 |
| 30 | 8510.45.30 | 8510.55.30 | 8510.65.30 |
| 35 | 8510.45.35 | 8510.55.35 | 8510.65.35 |
| 40 | 8510.45.40 | 8510.55.40 | 8510.65.40 |
| 45 | 8510.45.45 | 8510.55.45 | 8510.65.45 |
| 50 | 8510.45.50 | 8510.55.50 | 8510.65.50 |
Polyaxial Reduction Pedicle Screws are engineered to assist surgeons in gradually realigning displaced vertebrae during spinal fusion procedures. Featuring extended tulip heads (tabs) for controlled vertebral pulling and a multi-directional, swivel screw head, these screws allow for easier rod alignment and precise placement while minimizing stress on the screw-bone interface. This combination of flexibility and reduction capability provides secure vertebral anchorage and facilitates controlled deformity correction in complex spinal reconstructions.
Indications:| Codes / Diameter | |||
|---|---|---|---|
| Length in mm | 4.5 mm | 5.5 mm | 6.5 mm |
| 25 | 8515.45.25 | 8515.55.25 | 8515.65.25 |
| 30 | 8515.45.30 | 8515.55.30 | 8515.65.30 |
| 35 | 8515.45.35 | 8515.55.35 | 8515.65.35 |
| 40 | 8515.45.40 | 8515.55.40 | 8515.65.40 |
| 45 | 8515.45.45 | 8515.55.45 | 8515.65.45 |
| 50 | 8515.45.50 | 8515.55.50 | 8515.65.50 |
Iliac Pedicle Screws are engineered to provide robust anchorage within the Iliac bone, delivering exceptional stability in complex spinal and pelvic reconstructions. These screws are typically used in long spinal constructs where additional distal fixation is required, especially across the lumbosacral junction (L5–S1). Their design ensures strong biomechanical support, making them ideal for challenging deformity corrections and pelvic stabilization procedures.
Indications:| Codes / Diameter | ||
|---|---|---|
| Length in mm | 6.5 mm | 7.5 mm |
| 55 | 8520.65.55 | 8520.75.55 |
| 60 | 8520.65.60 | 8520.75.60 |
| 65 | 8520.65.65 | 8520.75.65 |
| 70 | 8520.65.70 | 8520.75.70 |
| 75 | 8520.65.75 | 8520.75.75 |
| 80 | 8520.65.80 | 8520.75.80 |
| 85 | 8520.65.85 | 8520.75.85 |
| 90 | 8520.65.90 | 8520.75.90 |
| 95 | 8520.65.95 | 8520.75.95 |
| 100 | 8520.65.100 | 8520.75.100 |
Dual Threaded Polyaxial Pedicle Screws feature two distinct thread patterns on the screw shaft — a coarse thread near the tip for strong purchase in cancellous bone, and a finer thread near the head for enhanced cortical bone engagement. The polyaxial head provides multi-directional movement, allowing flexible rod alignment during surgery. This design improves fixation strength and stability while facilitating easier surgical handling.
Indications:| Codes / Diameter | |||
|---|---|---|---|
| Length in mm | 4.5 mm | 5.5 mm | 6.5 mm |
| 25 | 8530.45.25 | 8530.55.25 | 8530.65.25 |
| 30 | 8530.45.30 | 8530.55.30 | 8530.65.30 |
| 35 | 8530.45.35 | 8530.55.35 | 8530.65.35 |
| 40 | 8530.45.40 | 8530.55.40 | 8530.65.40 |
| 45 | 8530.45.45 | 8530.55.45 | 8530.65.45 |
| 50 | 8530.45.50 | 8530.55.50 | 8530.65.50 |
HA (Hydroxyapatite) Coated Monoaxial Pedicle Screws combine a rigid, fixed-angle screw head with a bioactive hydroxyapatite coating that enhances bone growth and promotes faster, stronger osseointegration. This design ensures stable, controlled fixation and improved anchorage, particularly beneficial in patients with reduced bone quality. The monoaxial configuration aids in precise spinal alignment and deformity correction.
Indications:| Codes / Diameter | |||
|---|---|---|---|
| Length in mm | 4.5 mm | 5.5 mm | 6.5 mm |
| 25 | 8535.45.25 | 8535.55.25 | 8535.65.25 |
| 30 | 8535.45.30 | 8535.55.30 | 8535.65.30 |
| 35 | 8535.45.35 | 8535.55.35 | 8535.65.35 |
| 40 | 8535.45.40 | 8535.55.40 | 8535.65.40 |
| 45 | 8535.45.45 | 8535.55.45 | 8535.65.45 |
| 50 | 8535.45.50 | 8535.55.50 | 8535.65.50 |
HA (Hydroxyapatite) Coated Polyaxial Pedicle Screws are designed with a bioactive hydroxyapatite coating that promotes enhanced bone integration and faster osseointegration. The polyaxial head provides multi-directional mobility, allowing easier rod alignment during spinal fixation procedures. This combination improves screw stability, especially in patients with compromised bone quality, while facilitating flexible and secure spinal reconstruction.
Indications:| Codes / Diameter | |||
|---|---|---|---|
| Length in mm | 4.5 mm | 5.5 mm | 6.5 mm |
| 25 | 8538.45.25 | 8538.55.25 | 8538.65.25 |
| 30 | 8538.45.30 | 8538.55.30 | 8538.65.30 |
| 35 | 8538.45.35 | 8538.55.35 | 8538.65.35 |
| 40 | 8538.45.40 | 8538.55.40 | 8538.65.40 |
| 45 | 8538.45.45 | 8538.55.45 | 8538.65.45 |
| 50 | 8538.45.50 | 8538.55.50 | 8538.65.50 |
Fenestrated Monoaxial Pedicle Screws have a fixed screw head angle, providing rigid and stable fixation. The fenestrations along the screw shaft allow for cement augmentation, enhancing screw purchase in osteoporotic or weakened bone. This design offers controlled reduction capabilities combined with improved anchorage, making it suitable for demanding spinal surgeries requiring strong fixation and precise alignment.
Indications:| Codes / Diameter | ||
|---|---|---|
| Length in mm | 5.5 mm | 6.5 mm |
| 25 | 8541.55.25 | 8541.65.25 |
| 30 | 8541.55.30 | 8541.65.30 |
| 35 | 8541.55.35 | 8541.65.35 |
| 40 | 8541.55.40 | 8541.65.40 |
| 45 | 8541.55.45 | 8541.65.45 |
| 50 | 8541.55.50 | 8541.65.50 |
Fenestrated Polyaxial Pedicle Screws are designed with small holes (fenestrations) along the screw shaft, allowing for enhanced fixation through cement augmentation. The polyaxial screw head provides multi-directional mobility, facilitating easier rod placement and alignment during surgery. These screws combine the benefits of strong anchorage in osteoporotic or compromised bone with flexible handling for complex spinal procedures.
Indications:| Codes / Diameter | ||
|---|---|---|
| Length in mm | 5.5 mm | 6.5 mm |
| 25 | 8543.55.25 | 8543.65.25 |
| 30 | 8543.55.30 | 8543.65.30 |
| 35 | 8543.55.35 | 8543.65.35 |
| 40 | 8543.55.40 | 8543.65.40 |
| 45 | 8543.55.45 | 8543.65.45 |
| 50 | 8543.55.50 | 8543.65.50 |
Spinal Rods are metal bars that connect to Pedicle Screws to hold the Spine steady. They help maintain alignment, correct deformities, and support proper healing after surgery. Rods are typically made from titanium for strength and flexibility.
| Code | Dia in mm | Lenght in mm |
|---|---|---|
| 8547.50 | 5.5 | 50 |
| 8547.60 | 5.5 | 60 |
| 8547.70 | 5.5 | 70 |
| 8547.80 | 5.5 | 80 |
| 8547.90 | 5.5 | 90 |
| 8547.100 | 5.5 | 100 |
| 8547.110 | 5.5 | 110 |
| 8547.120 | 5.5 | 120 |
| 8547.130 | 5.5 | 130 |
| 8547.140 | 5.5 | 140 |
| 8547.150 | 5.5 | 150 |
| 8547.200 | 5.5 | 200 |
| 8547.250 | 5.5 | 250 |
| 8547.300 | 5.5 | 300 |
| 8547.350 | 5.5 | 350 |
| 8547.400 | 5.5 | 400 |
| 8547.450 | 5.5 | 450 |
| 8547.500 | 5.5 | 500 |
Connectors link Rods and Screws together or connect multiple rods when needed. They allow surgeons to customize the implant setup based on each patient’s Spine and surgical goals. Connectors play a key role in building a stable and adaptable spinal construct. They are made from Grade 5 Titanium.
| Code | Size |
|---|---|
| 8550-S | Small |
| 8550-M | Medium |
| 8550-L | Large |
Pedicle Staples are small implantable devices used to correct spinal deformities, such as Scoliosis, by guiding controlled growth of the Spine. Unlike traditional fusion methods, they allow for continued motion and growth in younger patients. They are easy to insert into the Pedicle. Made from medical grade Titanium.
Indications:| Code | Size |
|---|---|
| 8552-S | Small |
| 8552-L | Large |
Pedicle Hooks are used as anchoring components in posterior spinal instrumentation. Placed under or around the Pedicle, they provide strong fixation in cases where screws may not be suitable, such as in the upper Thoracic Spine or pediatric patients. Made from Medical Grade Titanium. Pedicle Hooks anchor onto the Lamina or Transverse Process, offering less invasive bony engagement and are especially useful in the Thoracic Spine.
Indications:| Code | Size |
|---|---|
| 8554-S | Small |
| 8554-L | Large |
Lamina Hooks are designed to engage the Lamina of the Vertebra to provide stable anchoring for posterior spinal constructs. They are especially useful in cases with compromised Pedicle bone quality or anatomical variation.
Indications:| Code | Size |
|---|---|
| 8556-S | Small |
| 8556-L | Large |
Minimally Invasive Surgery (MIS) Pedicle Screws are specialized spinal implants used to stabilize the Spine while minimizing tissue disruption. Designed for percutaneous insertion, these screws allow surgeons to achieve strong spinal fixation with smaller incisions, leading to reduced blood loss, quicker recovery, and less post-operative pain.
Indications:| Codes / Diameter | |||
|---|---|---|---|
| Length in mm | 5.5 mm | 6.5 mm | 7.5mm |
| 35 | 8855-35 | 8865-35 | 8875-35 |
| 40 | 8855-40 | 8865-40 | 8875-40 |
| 45 | 8855-45 | 8865-45 | 8875-45 |
| 50 | 8855-50 | 8865-50 | 8875-50 |
The Lateral Offset Connector is used to link Spinal Rods that are misaligned or placed at different lateral positions. It allows surgeons to adapt the construct to patient anatomy without compromising stability.
| Code | Size |
|---|---|
| 8565.20 | 20 mm |
| 8565.25 | 25 mm |
| 8565.30 | 30 mm |
| 8565.35 | 35 mm |
Transverse Connectors are used to link parallel Spinal Rods across the midline, providing added rotational and lateral stability to the construct. They are essential in long-segment or deformity correction procedures.
| Code No. | 8569.0001 |
|---|
Tapered Rods feature a gradual change in diameter along their length, allowing surgeons to customize spinal constructs with enhanced flexibility and strength where needed. This design helps accommodate anatomical variations and improves ease of implantation.
| Code No. | 8567.0001 |
|---|
Rods used with Transverse Connectors provide the main structural support in spinal fixation systems. These Rods are designed to connect securely with Transverse Connectors, ensuring a rigid and stable spinal construct.
| Code | Size |
|---|---|
| 8570.80 | 80 mm |
| 8570.100 | 100 mm |
| Codes / Diameter | ||
|---|---|---|
| Length in mm | 5.5 mm | 6.5 mm |
| 25 | 8795.25 | 8796.25 |
| 30 | 8795.30 | 8796.30 |
| 35 | 8795.35 | 8796.35 |
| 40 | 8795.40 | 8796.40 |
| 45 | 8795.45 | 8796.45 |
| 50 | 8795.50 | 8796.50 |
The combination of MIS Pedicle Screws and Curved Rods supports precise instrumentation while maintaining a less invasive surgical approach. Paired with curved rods, which are pre-contoured or customizable to follow the spine’s natural alignment, the system provides effective correction and stabilization in procedures like spinal fusion or deformity correction.
| Code | Size in mm |
|---|---|
| 8797.45 | 45 |
| 8797.50 | 50 |
| 8797.55 | 55 |
| 8797.60 | 60 |
| 8797.65 | 65 |
| 8797.70 | 70 |
| 8797.75 | 75 |
| 8797.80 | 80 |
| 8797.85 | 85 |
| 8797.90 | 90 |
| 8797.95 | 95 |
| 8797.100 | 100 |