Cable

A high-strength stainless steel cable designed for use with cable-ready plates, providing secure cerclage fixation in orthopedic reconstructive procedures. It offers reliable stabilization in complex cases where screw fixation alone may be insufficient.

Indications
  • Periprosthetic fractures requiring cerclage fixation
  • Supplemental stabilization in femoral reconstruction or revision surgeries
  • Fixation of comminuted or osteoporotic fractures
  • Trochanteric reattachment in hip arthroplasty
  • Securing bone fragments where screw fixation is inadequate or not feasible
Code - Titanium Dia. in mm Length in mm
Ti-SF-785.10-500 1.0 500
Ti-SF-785.12-500 1.2 500
Ti-SF-785.17-500 1.7 500

Curved Cable

A pre-contoured, high-strength stainless steel cable designed to match the natural curvature of the femur, ensuring secure and anatomical cerclage fixation when used with cable-ready plates. Its contoured design provides enhanced fit and stability in complex anatomical regions where straight cables may be insufficient.

Indications
  • Periprosthetic femoral fractures requiring contoured cerclage fixation
  • Trochanteric reattachment during hip arthroplasty
  • Femoral reconstruction in revision joint replacement
  • Fractures or osteotomies where curved cable placement improves fixation stability
  • Complex femoral anatomy where standard straight cables are inadequate
Code - Titanium Dia. in mm Length in mm
Ti-SF-784.10-500 1.0 500
Ti-SF-784.12-500 1.2 500

Flat Connector

A low-profile stainless steel connector designed to securely lock 1.0 mm, 1.2 mm, and 1.7 mm cables to cable-ready plates. It ensures stable cerclage fixation in orthopedic reconstructive procedures while maintaining a flat implant profile to minimize bulk and soft tissue irritation.

Indications
  • Securing cables to plates in periprosthetic fracture fixation
  • Cable anchoring in femoral reconstruction and revision surgeries
  • Applications requiring a flat, low-profile implant design
  • Cases where precise cable tension and reliable locking are critical for stability
Code Dia. in mm
Ti-SF-786.10 1.0
Ti-SF-786.17 1.7

Bone Needle

A specialized surgical instrument designed to facilitate the precise passage of cerclage cables or wires around bone during orthopedic procedures. Its design aids in controlled placement while minimizing soft tissue disruption, ensuring safe and efficient cerclage application.

Indications
  • Guiding cables or wires around the femur or other long bones
  • Facilitating cerclage fixation in periprosthetic and comminuted fractures
  • Use in revision arthroplasty for trochanteric reattachment or fracture stabilization
  • Minimizing soft tissue trauma during cable or wire placement
Code - S.S Dia. in mm Length in mm
SF-787.001 1.6 100
SF-787.003 1.6 110
SF-787.005 1.6 120
SF-787.007 1.6 130
SF-787.009 1.6 140
SF-787.011 2.0 100
SF-787.013 2.0 110
SF-787.015 2.0 120
SF-787.017 2.0 130
SF-787.019 2.0 140
SF-787.021 2.5 100
SF-787.023 2.5 110
SF-787.025 2.5 120
SF-787.027 2.5 130
SF-787.029 2.5 140

Bone Needle with Hole

A specialized bone needle featuring a distal hole for threading, designed to facilitate controlled passage of cerclage cables or wires around bone with improved precision and ease of use. Its design enhances surgical access in challenging anatomical regions while minimizing soft tissue disruption.

Indications
  • Assisting in the passage of cerclage cables or wires during orthopedic fixation
  • Facilitating cable placement in periprosthetic and complex femoral fractures
  • Use in revision arthroplasty for trochanteric or diaphyseal reconstruction
  • Minimizing tissue disruption and improving access in tight anatomical spaces
Code - S.S Dia. in mm Length in mm
SF-788.002 1.6 100
SF-788.004 1.6 110
SF-788.006 1.6 120
SF-788.008 1.6 130
SF-788.010 1.6 140
SF-788.012 2.0 100
SF-788.014 2.0 110
SF-788.016 2.0 120
SF-788.018 2.0 130
SF-788.020 2.0 140
SF-788.022 2.5 100
SF-788.024 2.5 110
SF-788.026 2.5 120
SF-788.028 2.5 130
SF-788.030 2.5 140